Field support / Retrofit devices
Get your readings
back on track.
A practical troubleshooting guide for retrofit devices that go offline, skip readings or report zero consumption. Start with the symptom you can see.
Issue 01
Device is not communicating
The device appears offline and no new data reaches the platform.
Possible causesPoor connectivity, a depleted battery, a device ID mismatch or a Sigfox callback configuration issue.
Start here: platform checks
- Open the dashboard and find Meter Info. Record Last Seen and compare it with the device’s expected reporting interval.
Open Meter Info and check Last Seen. Compare it with the device’s expected reporting interval. The time shown is an example. - Check the platform’s last recorded consumption. Select the relevant date range, choose Consumption Graph and apply the filter. Review the most recent recorded intervals alongside Last Seen; low or zero consumption alone does not confirm a communication fault.
Review the latest recorded consumption for the selected period and compare it with Last Seen. The readings shown are an example. View full-size screenshot (opens in a new tab). - Check Battery Status in Meter Info. If the status is Low or Empty, arrange battery or device replacement through an authorised technician. If the status is Ok, continue with the communication checks.
Low battery: arrange battery or device replacement through an authorised technician. View full-size screenshot (opens in a new tab). Empty battery: arrange battery or device replacement through an authorised technician. View full-size screenshot (opens in a new tab). - Ask an authorised technician with Sigfox backend access to check the latest message time, sequence-number gaps, receiving base stations, RSSI and LQI. Then verify the Smart-View UMS callback is linked and review callback delivery results. Check the device’s State as well: if it shows Off Contract, request reactivation through the team lead or support. See the examples below and expand Technician diagnostics for the follow-up checks.
Connectivity example: compare the latest message time with the current time and expected reporting interval. Review the sequence-number gap from 787 to 792 alongside the receiving stations, RSSI and LQI; a gap alone does not establish the cause. View full-size screenshot (opens in a new tab). Callback examples: a red indicator marks failed delivery. The separate 200 Success response illustrates a successful callback. Confirm that the Smart-View UMS callback is linked to the device and escalate failed delivery to support. View full-size screenshot (opens in a new tab). Off Contract example: check the device’s State as well as its communication status. Request reactivation through the team lead or support when the device is off contract, then verify that messages reach Sigfox and the platform. Device-specific registration details are hidden. View full-size screenshot (opens in a new tab). - Compare the device ID on the platform with the device sticker or installation job card.
Technician diagnostics
For authorised technicians with the required platform and device access. Follow your organisation’s site-visit approval process before field work. Short codes apply to compatible devices and readers.
- In the Sigfox backend, check whether messages are arriving. Review sequence-number gaps, base-station count, RSSI and LQI together to investigate connectivity.
- Check that the device is Active and that its Smart-View UMS callback is linked. Review failed callbacks with support; request reactivation through the team lead if the device is inactive.
- On site, use 7# on a compatible CIU reader to view battery voltage. If the reader reports No Unit, check that it is seated securely and escalate if the message persists. Arrange battery or device replacement where required, following the approved device-specific procedure.
Example of an opened retrofit device enclosure. Only an authorised technician should open the device or replace its battery, following the approved procedure for the installed model. - For a suspected coverage issue, place a test device near the installation and use 20# to send a test message. Confirm receipt in Sigfox, then compare reception at a suitable location with clearer coverage. Verify repeated successful messages before confirming any relocation.
- If relocation requires extending the wiring, reprogramme the start reading using the approved setup procedure. Escalate if communication cannot be restored.
When to contact support
Contact support if the device remains offline after these checks, the device is inactive, or callbacks fail. Include the device ID, Last Seen, battery status and screenshots.
Issue 02
Device is skipping readings
The device communicates, but some expected readings are missing.
Possible causesPoor or unstable network coverage and interference at the installation location can cause gaps.
Start here: platform checks
- Open the dashboard’s Readings Graph and select Readings Table. Choose the relevant date range and check the DateTime column against the configured daily or hourly reporting interval. Record the missing intervals shown in the table.
Daily reporting example: compare consecutive dates in the highlighted DateTime column with the expected daily schedule. Record the missing days for support. The meter identifier is hidden. View full-size screenshot (opens in a new tab). Hourly reporting example: look for missing hours in the highlighted DateTime column, including the gap between 20:03 and 22:04. Check the full selected period when documenting gaps. The meter identifier is hidden. View full-size screenshot (opens in a new tab). - Ask an authorised technician with Sigfox backend access to compare the missing platform intervals with the message timestamps and sequence numbers. Review receiving base stations, RSSI, LQI and callback results together. Sequence-number gaps help identify messages to investigate; they do not establish the cause on their own.
Daily Sigfox example: compare message dates with the platform’s missing days. Investigate the sequence-number gap from 787 to 792 alongside the receiving stations, RSSI, LQI and callback results. View full-size screenshot (opens in a new tab). Hourly Sigfox example: the highlighted sequence numbers jump from 487 to 489. Match the timestamps to the missing platform intervals and review signal quality and delivery results with support. View full-size screenshot (opens in a new tab). - Note when the gaps began and whether they affect one device or several devices at the site.
- Check Battery Status in Meter Info and capture examples of the missing intervals for support.
Technician diagnostics
For authorised technicians with the required platform and device access. Follow your organisation’s site-visit approval process before field work. Short codes apply to compatible devices and readers.
- Compare the platform’s missing intervals with messages in the Sigfox backend. Look for skipped sequence numbers and review base-station count, RSSI and LQI.
- Check the battery on site using 7# with a compatible CIU reader. Arrange replacement for a Low or Empty battery indication under the approved procedure.
- Use a test device and 20# to compare reception at the installed position and an alternative location. Confirm repeated successful delivery in Sigfox before relocating the device.
- Reprogramme the start reading if the wiring is extended during relocation. Escalate to the team lead when signal quality remains poor.
When to contact support
Contact support when gaps continue or signal remains poor after a location check. Include the expected reporting interval and examples from the reading table.
Issue 03
Device is sending zero readings
Messages arrive, but consumption is zero or the readings stay flat.
Possible causesIncorrect wiring, a loose reed switch, a faulty sensor or a meter that is not registering flow.
Start here: platform checks
- Open Meter Info and record any Error Code, such as No Flow or Meter Pulses. Review the Readings Table to check whether usage is zero and whether the device and meter readings remain unchanged across consecutive transmissions.
Record the exact error shown in Meter Info. No Flow or Meter Pulses should be investigated alongside the physical meter reading and sensor checks. View full-size screenshot (opens in a new tab). Zero-reading example: messages arrive hourly, while Device Reading and Meter Reading stay unchanged and Usage remains 0.000 kl. Compare this pattern with actual flow and the physical meter before diagnosing a fault. View full-size screenshot (opens in a new tab). - Review the installation job card and existing photographs with support. Ask an authorised technician to compare the connector wiring with the guide for the exact meter and sensor, confirm wires are fully seated, and check that any reed switch is fully inserted and secure. Capture clear photographs of both sides of the connectors and the installed sensor.
Connector evidence: provide clear photographs of the front and back of each connector. An authorised technician should verify wire seating and connections against the meter-specific wiring guide. Wire colours depend on the installed model. View full-size screenshot (opens in a new tab). Reed-switch evidence: photograph the sensor at the meter. An authorised technician should check that the correct sensor is fully inserted and secure, using the instructions for the installed meter. View full-size screenshot (opens in a new tab). - Compare the physical meter reading with the recorded installation reading, where the meter can be accessed safely.
Technician diagnostics
For authorised technicians with the required platform and device access. Follow your organisation’s site-visit approval process before field work. Short codes apply to compatible devices and readers.
- Compare the physical meter reading with the job card. Where permitted and practical, run water to confirm that the meter registers flow.
- Wait for the next expected transmission and check whether the platform reflects the changed reading.
- Use the wiring guide for the exact meter and sensor. Check the connections and confirm that wires are fully seated in their connectors. Capture clear photographs of the front and back of the connectors.
- For a reed-switch installation, check that the sensor is fully inserted and secure. Photograph the installed sensor for the support record.
- If the meter registers flow but the device still reports no change after the connection checks, arrange sensor or device assessment and replacement as appropriate. Escalate unresolved faults to the team lead.
When to contact support
Contact support if the physical meter changes but the platform reading stays flat after the next transmission, or if the sensor or wiring needs attention.
After the fix
Confirm the readings are right.
After a device replacement, the authorised platform operator should:
- Ensure the previous billing cycle is closed before changing the device record.
- Update the device ID for a like-for-like SmartWater replacement; add a new device when the replacement type differs.
- Capture the start reading and its date and time. Check how both devices were programmed before deciding whether previous readings should be ignored; confirm the choice with support if unsure.
- For hourly reporting, monitor at least five hours of readings and check the totalizer. For daily reporting, verify the next day’s reading.
Keep the investigation moving
Still need a hand?
Send your device ID, site name, reporting interval, Last Seen, battery status and any error code. Include relevant reading-table screenshots and installation photographs, plus the job card and warranty status when available.